Disconnecting Means Enclosure as a Raceway | Mike Holt's Forum

    https://forums.mikeholt.com/threads/disconnecting-means-enclosure-as-a-raceway.2556366/#:~:text=You%20cannot%20use%20the%20space%20in%20a%20switch,come%20out%20of%20a%20service%20meter%20only%20once.
    none

Disconnect as a raceway | Mike Holt's Forum

    https://forums.mikeholt.com/threads/disconnect-as-a-raceway.55369/
    There is an area where the contrator installed Disconnects at HVAC units and a receptacle at each disconnect. The pulled the Recpt. feed in with the AC feed in the same conduit, entered the disconnect and then took the recpt. circuit into a conduit nipple which goes to the recpt. box. In short, they used the disconnect as a raceway.

Disconnecting Means Enclosure as a Raceway | Mike …

    https://forums.mikeholt.com/threads/disconnecting-means-enclosure-as-a-raceway.2556366/
    Yikes! You cannot use the space in a switch devoted to conductor airspace as a raceway. You would need to put a raceway over the top of the disconnect means (trough) and come down to feed respective disconnects. …

Disconnect as raceway. | Electrician Talk

    https://www.electriciantalk.com/threads/disconnect-as-raceway.43007/
    TimChaput69 said: Now that I've found the code ref, thats made me think about it!!! Actually it could be a code violation depending on the conditions. Example: 208V, 3 phase, circuit in a 250V disconnect, by code you can't bring another 120v circuit through because then you violate the UL listing of disconnect ,then you'll be over 250V, correct ...

Disconnect used as a raceway question. : electricians

    https://www.reddit.com/r/electricians/comments/uhg7r6/disconnect_used_as_a_raceway_question/
    Disconnect used as a raceway question. Can a disconnect be used as a feed thru enclosure? It meets all the requirements of NEC 312.8 (A)1,2,3. It mentions “….shall be permitted for conductors feeding thru to other enclosures, switches, or overcurrent devices…”.

Using a Panel or Disconnect as a Raceway : electricians

    https://www.reddit.com/r/electricians/comments/6fmx3s/using_a_panel_or_disconnect_as_a_raceway/
    312.8 says you can if you follow the rules. 300.3 says that mixing voltages is legal too, as long as the lower voltage conductors have equal or higher insulation rating as the higher rated voltages in the raceway or enclosure. Hope that is enough to get you started. 5 level 2 KyleKilroy Op · 5y Thank you, 312.8 answered my question. 1

Can you use an electrical panel as a feed-through raceway ...

    https://www.howtolookatahouse.com/Blog/Entries/2021/2/can-you-use-an-electrical-panel-as-a-feed-through-raceway-for-wiring-that-is-not-connected-to-it.html
    Yes, wiring can pass through a panel without needing to have any electrical connections to it, according to the National Electrical Code (NEC-312.8). But the additional wiring cannot make the box become overpacked [NEC-312.8(A)(1,2)], and a warning label must be applied to the enclosure that identifies the closest disconnecting means for the feed-through …

Wiring through Service Disconnects - IEEE (electrical ...

    https://www.eng-tips.com/viewthread.cfm?qid=64412
    This is a code violation as enclosures cannot be used as a raceway. Enclosures are typically sized to accomadate wire in and out of the device. In addition, the splice within the enclosure is a potential for a fault, which could damage you service entrance disconnect, even though the Burndy Unitaps are a good product for connection of multiple connections.

Understanding Raceways | EC&M

    https://www.ecmweb.com/national-electrical-code/code-basics/article/20903368/understanding-raceways
    You can use galvanized steel and stainless steel EMT, elbows, and fittings in concrete, in direct contact with the earth, or in areas subject to severe corrosive influences if protected by corrosion protection and approved as suitable for the condition [Sec. 300.6(A)]. You can’t use EMT [Sec. 358.12]: (1) Where subject to severe physical damage.

Types Of Raceways | Conduit vs Raceway | Gracon LLC

    https://graconllc.com/types-of-raceways/
    Altogether, very few types of conductors are rated to be used without a raceway system. Most conductors require some form of protection to prevent any damage.

What Is the Difference Between a Raceway and a Conduit ...

    https://www.eswick.com/what-is-the-difference-between-raceway-and-conduit
    Gene Hatfield. A conduit is a tube or trough that is used to protect electrical wires. A raceway is a confined conduit that serves as a physical conduit for electrical wiring. Heat, humidity, corrosion, water incursion, and other physical dangers are all mitigated by raceways. Raceways are commonly used in homes, offices, retail spaces, and ...