romex trasition to/from raceway code - DoItYourself.com ...

    https://www.doityourself.com/forum/electrical-ac-dc/478238-romex-trasition-raceway-code.html
    3. instead of the metal raceway, does the code allow covering the surface-run romex in plastic raceway (not a conduit). yes or no? (seen both answers) and my question is not on the quality of the job but that of code. thanks ps...as far as the romex in the fake beam is concerned, i can always use a conduit since it will not be visible Upvote # 2

is it acceptable to run 14/2 romex inside of wiremold raceway?

    https://www.justanswer.com/electrical/7mg7k-acceptable-run-14-2-romex-inside-wiremold-raceway.html
    i was planning on ending the wiremold just above the ceiling tiles. im only running wiremold to make it look nice. its a cement wall so running in the wall is not practical. and i know romex cannot be run when it will be exposed to potential damage. its only 5 ft from the ceiling line to where the outlet box will be placed. just wondering the best course of action for doing this so …

Can I Run Romex In Conduit? What You Need To Do - Monkey ...

    https://mnkbusiness.com/can-i-run-romex-in-conduit/
    none

How to Cover Exposed Romex – Upgraded Home

    https://upgradedhome.com/how-to-cover-exposed-romex/
    ROMEX is a type of non-metallic sheathed cable that you can find in countless homes, but it should never be left exposed. Exposed wires can create a major safety hazard, so the best option is to place them within a PVC conduit to reduce risk. Whether it be PVC, ENT, or EMT, let’s take a look at the best way to cover your exposed ROMEX wires.

Can I use Romex outside? - AskingLot.com

    https://askinglot.com/can-i-use-romex-outside
    No. Romex+outside in conduit= wet location. Conduit which is not subject to any weather would be OK, but very few outdoor locations fit that description. The bottom line is this: if you could use NM there without conduit, then you could sleeve it in conduit. Furthermore, can nm b wire be used outdoors?

romex in wiremold as sleeve? | Mike Holt's Forum

    https://forums.mikeholt.com/threads/romex-in-wiremold-as-sleeve.62494/
    MetroWest, MA. Apr 16, 2009. #1. I think I can do this legally but here is the situation. I need to run a circuit to the kitchen from the panel which is recessed in the wall in the living room about 30 ft. No access from above or below so they are requesting wiremold 500 surface mounted up high on the wall with 12/2 romex (NM cable) sleeeved ...