External ground wire - Electrician Talk

    https://www.electriciantalk.com/threads/external-ground-wire.28969/#:~:text=Very%20few%20EGCs%20can%20be%20run%20outside%20the,lightning%20protection%20scheme%20that%20exceeds%20any%20NEC%20requirements.
    none

Can I run a ground wire of a single circuit to the panel …

    https://diy.stackexchange.com/questions/10623/can-i-run-a-ground-wire-of-a-single-circuit-to-the-panel-outside-the-house
    Equipment grounding conductors shall be permitted to be installed outside a raceway or cable assembly where in accordance with the provisions of 250.130 (C) for certain existing installations or in accordance with 250.134 (B), Exception No.2, for DC circuits.

Ground wire on outside of conduit - Mike Holt's Forum

    https://forums.mikeholt.com/threads/ground-wire-on-outside-of-conduit.43757/
    #1 Ive always ran the ground wire on the inside with the other conductors when not using the raceway as a egc. Had a situation where a transformer was installed and we had the feeders for the transformer inside the raceway and the ground wire was later added after on the outside of the race way by others.

External ground wire - Electrician Talk

    https://www.electriciantalk.com/threads/external-ground-wire.28969/
    grounding conductors shall be permitted to be installed outside a raceway or cable assembly where in accordance with the provisions of 250.130(C) for certain existing installations or in accordance with 250.134(B), Exception No. 2, for dc circuits. Equipment bonding conductors shall be permitted to be installed on the outside of raceways in accordance

ground wires and grounding conduit sleeves/raceway

    https://www.diychatroom.com/threads/ground-wires-and-grounding-conduit-sleeves-raceway.491290/
    I'd run a #6 ground wire, either with the green jacket or just bare. Land one end on the ground bar in main panel, and then use water pipe clamps for the appropriate size (1/2"-1" should work) and ground it that way. One ground wire for both will suffice. Do it once, do it to code the first time.

Insulated vs. Bare Ground Wire Application - Mike Holt's …

    https://forums.mikeholt.com/threads/insulated-vs-bare-ground-wire-application.143220/
    It's not the greatest idea to pull bare stranded wire with other conductors in a wire pull, and solid conductors larger than 8awg, IIRC, are not allowed to be pulled in raceways. Smooth outer insulation of THHN probably makes for an easier pull in many cases. For GECs run outside raceways the insulation provides a bit of extra protection from damage.

Bare or Insulated? Choosing the Best Grounding Wire for …

    https://www.kristechwire.com/bare-or-insulated-grounding-wire/
    In the event of a short circuit or power surge, the excess electricity safely travels through the ground wire to the earth, rather than through equipment (or people!) that may be nearby. In this way, grounding helps prevent serious injuries, equipment damage, and potential fires. ... Busbars are typically uninsulated, so insulated grounding ...

Ground Wire Insulated? in Conduit? - DoItYourself.com

    https://www.doityourself.com/forum/electrical-ac-dc/67988-ground-wire-insulated-conduit.html
    Running bare ground inside the PVC conduit is fine. Inside is better than outside in case you ever need to service it or if your demand out there increases pulling larger conductors and a larger ground. In 1-1/4" sch 40 PVC you're permitted up to four #4 wires, and this gauge will get you 100 amps. I'd size it for future expansion.

Bare Ground in Conduit? - Mike Holt's Forum

    https://forums.mikeholt.com/threads/bare-ground-in-conduit.10968/
    All conductors are required to be insulated per section 310.2 (A), however the exception states bare conductors are allowed where permitted by other sections of the code, such as 250.119 which states egc can be bare, covered, or insulated. I agree, but if you are using ANY aluminum raceways (elbows or entire runs)DO NOT use bare copper.

Bare Ground in EMT? | Electrician Talk

    https://www.electriciantalk.com/threads/bare-ground-in-emt.2188/
    Safety-Guy said: It has recently been interpreted by an AHJ in FL that pulling bare copper ground wire in metal conduit is a code violation. We have asked for a code reference, but I suspect it will be 342.14 , 344.14, or 358.12 (6). If anyone knows of any code reference that would contradict this ruling, please let me know your input.

Insulated Grounding of a Spa or Hot Tub - Mike Holt's Forum

    https://forums.mikeholt.com/threads/insulated-grounding-of-a-spa-or-hot-tub.47348/
    A conduit or raceway, even if 100% waterproof, is not a location. The EGC should probably be insulated for a couple of reasons: 1) it will last longer, and 2) not contribute to shock hazard. Typically, the few inches of an indoor wiring method are accepted to terminate in an outside disco enclsure, such as an AC unit.