Disconnecting Means Enclosure as a Raceway | Mike Holt's Forum

    https://forums.mikeholt.com/threads/disconnecting-means-enclosure-as-a-raceway.2556366/#:~:text=You%20cannot%20use%20the%20space%20in%20a%20switch,come%20out%20of%20a%20service%20meter%20only%20once.
    none

Disconnect as a raceway | Mike Holt's Forum

    https://forums.mikeholt.com/threads/disconnect-as-a-raceway.55369/
    There is an area where the contrator installed Disconnects at HVAC units and a receptacle at each disconnect. The pulled the Recpt. feed in with the AC feed in the same conduit, entered the disconnect and then took the recpt. circuit into a conduit nipple which goes to the recpt. box. In short, they used the disconnect as a raceway.

Disconnect as raceway. | Electrician Talk

    https://www.electriciantalk.com/threads/disconnect-as-raceway.43007/
    Thanks for the point in the right direction, always thought it was not legal to run 480v and 120v in same raceway then through the disconnect and into a receptacle. Save Reply W wingz Registered Joined Mar 21, 2009 229 Posts #4 · Sep 5, 2012 TimChaput69 said:

The use of a disconnect as a raceway. | Mike Holt's Forum

    https://forums.mikeholt.com/threads/the-use-of-a-disconnect-as-a-raceway.63445/
    The use of a disconnect as a raceway. | Mike Holt's Forum Home Forums Active Forums NEC The use of a disconnect as a raceway. sparkky302 May 12, 2009 Not open for further replies. S sparkky302 Member May 12, 2009 #1 What I have is a disconnect outside of a building that feeds a condensor unit. The disconnect is fed with a 3/4" conduit.

Using a Panel or Disconnect as a Raceway : electricians

    https://www.reddit.com/r/electricians/comments/6fmx3s/using_a_panel_or_disconnect_as_a_raceway/
    312.8 says you can if you follow the rules. 300.3 says that mixing voltages is legal too, as long as the lower voltage conductors have equal or higher insulation rating as the higher rated voltages in the raceway or enclosure. Hope that is enough to get you started. 5 level 2 KyleKilroy Op · 5y Thank you, 312.8 answered my question. 1

Can you use an electrical panel as a feed-through raceway ...

    https://www.howtolookatahouse.com/Blog/Entries/2021/2/can-you-use-an-electrical-panel-as-a-feed-through-raceway-for-wiring-that-is-not-connected-to-it.html
    Yes, wiring can pass through a panel without needing to have any electrical connections to it, according to the National Electrical Code (NEC-312.8). But the additional wiring cannot make the box become overpacked [NEC-312.8(A)(1,2)], and a warning label must be applied to the enclosure that identifies the closest disconnecting means for the feed-through …

Understanding Raceways | EC&M

    https://www.ecmweb.com/national-electrical-code/code-basics/article/20903368/understanding-raceways
    You can use galvanized steel and stainless steel EMT, elbows, and fittings in concrete, in direct contact with the earth, or in areas subject to severe corrosive influences if protected by corrosion protection and approved as suitable for the condition [Sec. 300.6(A)]. You can’t use EMT [Sec. 358.12]: (1) Where subject to severe physical damage.

Wiring through Service Disconnects - IEEE (electrical ...

    https://www.eng-tips.com/viewthread.cfm?qid=64412
    This is a code violation as enclosures cannot be used as a raceway. Enclosures are typically sized to accomadate wire in and out of the device. In addition, the splice within the enclosure is a potential for a fault, which could damage you service entrance disconnect, even though the Burndy Unitaps are a good product for connection of multiple connections.

Choosing the Right Raceway | EC&M

    https://www.ecmweb.com/national-electrical-code/code-basics/article/20896212/choosing-the-right-raceway
    Turn to Sec. 10 of Art. 342 and Art. 358, and read the Uses Permitted. Then, read the Uses Not Permitted in Section 12. This will tell you if you can use either wiring method for a particular application. If both pass this test, then you can work through each Article and compare the requirements of the two raceways. Sidebar: Conduit Vs. Tubing

If you have a ac disconnect on a compresor can you use the ...

    https://www.justanswer.com/electrical/2duop-ac-disconnect-compresor-use.html
    No you cannot. Even though they are serving the same equipment, they are completely different voltages. So you will not be able to run them in the same raceway. They will have to remain separate.

meter socket as raceway | The Building Code Forum

    https://www.thebuildingcodeforum.com/forum/threads/meter-socket-as-raceway.9073/
    After all of these years the local power company rep will not allow a reconnect as the power has been off recently to his bldg. I'm not even sure it's a code violation except for the can is used as a raceway. And even with that there's enough room and bending space in the can. What say you folks? I think it's chicken stools. BSSTG Dennis