Support and Bracing Requirements for Ceiling …

    https://www.sanjoseca.gov/Home/ShowDocument?id=27495
    none

Armstrong Ceiling S

    https://www.armstrongceilings.com/static/assets/commceilingsna/cadrevit/Splay%20Wire%20Bracing%20and%20Compression%20Post.pdf
    Created Date: 11/7/2008 1:21:24 PM

Sloped Ceilings Technical Guide - Armstrong Ceiling S

    https://www.armstrongceilings.com/content/dam/armstrongceilings/commercial/north-america/technical-guides/sloped-ceilings-technical-guide.pdf
    • If lateral force bracing is required in severe seismic areas, it shall remain vertical and the splay wires shall be installed at maximum 45° to the horizontal. Lateral Force Bracing (Compression Posts and Splay Wires) shim Vertical Hanger Wire Adjacent to Bracing Vertical Hanger Wire Adjacent to Bracing Vertical Hanger Wire Adjacent to Bracing

Suspended Ceiling Seismic Assemblies

    https://www.usg.com/content/dam/USG_Marketing_Communications/united_states/product_promotional_materials/finished_assets/seismic-technical-guide-suspended-ceiling-seismic-assemblies-en-SC2233.pdf
    Lateral Splay Bracing 1. Refers to CISCA installation recommendations for zones 0-2 via ASCE 7. Max ceiling weight: 2.5 psf. 2. Refers to CISCA installation recommendations for zones 3-4 viaASCE 7. 3. All USG Donn® brandinstalling ceiling suspension systems meet these requirements. 4. PerASTM C635. 5. Required for ceilings larger than 1,000 square feet.

SUSPENDED CEILINGS Suspension Systems for Acoustical …

    https://www.nwcb.org/uploads/4/0/5/0/40504193/401_revised_1217.pdf
    • Splay wires are to be within 2 inches of the connection of the vertical strut to suspended ceiling. Source: ASTM E580 Section 5.2.8.2 • Rigid bracing may be used in lieu of splay wires. Source: ASTM E580 Section 5.2.8.4 • Ceilings with plenums less than 12 inches to structure are not required to have lateral-force bracing.

SUSPENDED CEILINGS Suspension Systems for Acoustical …

    https://web.nwcb.org/External/WCPages/WCWebContent/webcontentpage.aspx?ContentID=1327
    • Lateral-force bracing splay wires shall consist of four 12-gauge wires attached to the main beam, arrayed 90° from each other and at an angle not exceeding 45° from the plane of the ceiling. Source: ASTM E580 Section 5.2.8.2 • Lateral-force bracing splay wires shall be attached to …

Technical Document Seismic Technical Guide - USG

    https://www.usg.com/content/dam/USG_Marketing_Communications/united_states/product_promotional_materials/finished_assets/seismic-technical-guide-partition-attachment-en-SC2505.pdf
    Walls or partitions shall only be attached to ceiling suspension provided they allow the ceiling membrane to move laterally to accommodate the required clearance, minimum 3/8 in. (9 mm). Requirements Partitions that are tied to the ceiling and all partitions greater than 6 ft (1.8 m) in height shall be laterally braced to the building structure.

COMMERCIAL SUSPENDED CEILINGS-RMc 9.27.12

    https://www.cityofpaloalto.org/files/assets/public/development-services/building-division/commercial-guidelines/inspections/suspended-ceiling-systems-10.24.2012-[27286].pdf
    Partitions that are tied to the ceiling and all partitions greater than 6ft in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. Bracing shall be spaced to limit horizontal deflection at the partition head to be

Seismic Technical Guide CertainTeed Acoustical …

    https://www.certainteed.com/resources/SeismicSecureTech_Brochure_CTC06-301_2006_E.pdf
    BRACING REQUIREMENTS (For areas > 1000 S.F.) Horizontal restraint (splay wires or rigid bracing) within 2" of intersection and splayed 90° apart at 45° angles (areas over 1,000 ft2) Not required Required Not required Required Compression posts (struts) 12' o.c. in both directions, starting 6' from walls

Cracking the Code: Attaching Partitions To Suspended …

    https://www.wconline.com/articles/85204-cracking-the-code-attaching-partitions-to-suspended-ceilings
    The ASCE 7-02 standard and the IBC section 1621.1.2 state that, “partitions that are tied to the ceiling and all partitions greater than 6 feet in height shall be independent of any splay bracing.”. The intent by code officials is not to allow the use of the suspended grid system as bracing support for the partition.