BRACING CONCRETE MASONRY WALLS UNDER …

    https://ncma.org/resource/bracing-concrete-masonry-walls-under-construction/
    Determine the bracing requirements for a 22 ft (6.71 m) tall wall constructed with 8 in. (203 mm) concrete masonry having a density of 110 lb/ft 3 (1762 kg/m 3) …

OSHA Masonry Wall Bracing Requirements: A Contractor’s Guide

    https://www.bracingsystems.com/osha-masonry-wall-bracing-requirements-a-contractors-guide
    OSHA’s Rules on Limited Access Zones. they must be established prior to the start of construction of the wall; they must equal to the height of the wall to be constructed plus four feet, and shall run the entire length of the wall; they must be …

IRC Wall Bracing Requirements for Load Bearing CMU …

    https://www.eng-tips.com/viewthread.cfm?qid=353389
    RE: IRC Wall Bracing Requirements for Load Bearing CMU Walls? msquared48 (Structural) 25 Oct 13 18:12 280# per foot minimum or the seismic value calculated for parts of a structure, whichever is greater.

Masonry wall bracing requirements. | Occupational Safety …

    https://www.osha.gov/laws-regs/standardinterpretations/1996-06-25
    As you recognize, the requirement to install bracing applies to all masonry walls over eight feet tall that are not otherwise adequately supported. This is the case whether the wall contains reinforcing steel (rebar) or not.

Wall Bracing 101 - Mason Contractors

    https://masoncontractors.org/2004/09/13/wall-bracing-101/
    be equal to the height of the wall plus four feet and run the length of the wall; be established on the unscaffolded side of the wall; be restricted to entry by only the mason contractor; and. remain in place until the wall is adequately supported. Photo courtesy of Jakerstin Bracing, Inc.

Bracing Masonry Walls - Mason Contractors

    https://masoncontractors.org/2005/07/25/bracing-masonry-walls/
    Braces must be installed with 20% of the wall outside of each brace at the control joint. The easiest way to figure this is to take the panel length and multiply by .2. For example, a 25' long wall multiplied by .2 would leave each brace located at 5' from the control joints and 15' between the braces.

DESIGNING CONCRETE MASONRY WALLS FOR WIND …

    https://ncma.org/resource/designing-concrete-masonry-walls-for-wind-loads/
    Traditionally, empirical requirements have been used for the selection of masonry wall dimensions and lateral support spacing for resistance to wind pressures. These empirical requirements provide satisfactory results for buildings less than 35 ft (11 m) in height where the basic wind pressure does not exceed 25 psf (1197 Pa).

Bracing A m a s o n r y walls: W h y, when, w h e r e, and how

    https://www.concreteconstruction.net/_view-object?id=00000154-22dd-db06-a1fe-73ddaa390000
    crete masonry walls must be braced, based on the design wind speed and the weight of the wall. Weights of concrete masonry walls and brick-block com-posite walls can be found in Table 1 . Determining the appropriate design wind speed is more difficult. Most building codes recognize that wall bracing and other temporary sup-

1926.706 - Requirements for masonry construction.

    https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.706
    Part Number: 1926. Part Number Title: Safety and Health Regulations for Construction. Subpart: 1926 Subpart Q. Subpart Title: Concrete and Masonry Construction. Standard Number: Title: Requirements for masonry construction. GPO Source: e-CFR.