Interested in racing? We have collected a lot of interesting things about Ecoply Nz Bracing. Follow the links and you will find all the information you need about Ecoply Nz Bracing.
Ecoply® Barrier » Plywood NZ
https://chhply.co.nz/ranges/ecoply/ecoply-structural-plywood/barrier/
The Ecoply Barrier System meets the NZ Building Code requirements for rigid underlays as outlined in Section 9.1.4; the performance requirements of Table 23 of E2/AS1; and has been tested for wind speed exceeding Extra High wind zone as defined in NZS 3604. Testing has been completed to provide solutions for buildings outside scope of NZS 3604 ...
ECOPLY BRACING SPECIFICATIONS: EP2 - Plywood NZ
https://chhply.co.nz/assets/Uploads/b244fc6694/Ecoply-Bracing-EP2-Specification-Tech-Note-April-2016.pdf
For further information contact Customer Services on 000 326 5 or visit www.chhwoodproducts.co.nz PAGE 1 Ecoply® Bracing Systems are designed to meet the requirements of the New Zealand Building Code and have been tested and analysed using the P21 method referenced in NZS 3604:2011 listed as an acceptable solution B1/AS1 Structure.
Ecoply Bracing Specification EP1 - organonarchitecture.co.nz
http://www.organonarchitecture.co.nz/CLIENTS/Bishop-Blackmore/ConsentDocs/Ecoply%20Bracing%20-%20EP1%20Specification%20(Apr-09).pdf
www.chhwoodproducts.co.nz www.ecoply.co.nz N Ecoply® Bracing Specification – EP1 April 2009 Single sided structural plywood brace Specification No. Minimum Wall Length Lining Requirements BUs/m Wind BUs/m Earthquake EP1 0.6 m 7mm Ecoply® or 12mm Shadowclad® one side 130 130 Framing Wall framing must comply with:
Ecoply Bracing Specification - EPG - organonarchitecture.co.nz
http://www.organonarchitecture.co.nz/CLIENTS/Bishop-Blackmore/ConsentDocs/Ecoply%20Bracing%20-%20EPG%20Specification%20(Apr-09).pdf
www.chhwoodproducts.co.nz www.ecoply.co.nz 2 N Fastening the GIB® Plasterboard Fasteners 32mm x 6g GIB® Grabber® Screws or 35mm GIB® Nails. Fastener Centres Fasten 50, 100 and 150mm from each corner and 150mm thereafter around the perimeter of the bracing element. For vertical fixing place fasteners at 300mm centres at intermediate sheet ...
BARRIER
https://www.ecoplybarrier.co.nz/assets/Uploads/201402-CHH-Ecoply-BarrierEPBGTechnicalNote-v1.00.pdf
Ecoply® Bracing Systems are designed to meet the requirements of the New Zealand Building Code and have been tested and analysed using the P21 method referenced in NZS 3604:2011 listed as an acceptable solution B1/AS1 Structure. Testing was carried out using Ecoply Barrier manufactured by Carter Holt Harvey and SG8 timber
Ecoply® Barrier Rigid Air Barrier | BRANZ
https://www.branz.co.nz/appraisal-codemark-certificates/827-2019-ecoply-barrier-rigid-air-barrier/
Description. The Ecoply® Barrier Rigid Air Barrier is sealed plywood sheets and tapes designed for use as a rigid wall underlay and air barrier (sheathing) behind cavity wall cladding systems. Ecoply® Barrier is also for use as a wall bracing system to resist wind and earthquake loads on timber-framed buildings.
Ecoply® Plywood » Plywood AU
https://chhply.com.au/ranges/ecoply/products/
Commonly used for flooring, bracing, interior linings, membrane substrates, hoardings and DIY projects, Ecoply plywood products provide durability, strength and design flexibility. ... Manufactured from sustainably grown Australian and New Zealand Plantation Radiata Pine. Ecoply products (excluding the non-structural range) are produced and ...
ECOPLY SPECIFICATION & INSTALLATION GUIDE
https://www.redmantle.co.nz/wp-content/uploads/2017/09/PLY_Ecoply-Specification-Guide-2014-WEB-050514-2.pdf.pdf
CHH WOODPRODUCTS | |ECOPLY ® 0800 326 759 | www.chhwoodproducts.co.nz 3 1.0 ECOPLY® PRODUCT RANGE The information contained in this manual relates specifically to Ecoply® branded structural plywood manufactured by Carter Holt Harvey® Woodproducts and cannot be used with any other plywood manufacturers product however similar they may appear.
BARRIER
https://www.ecoplybarrier.co.nz/assets/Uploads/2017-CHH-EcoplyBarrier-SpecificationAndInstallationGuide-v1.01-Web.pdf
6 CHH WOODPRODUCTS ® || ECOPLY BARRIER 0800 326 759 | www.chhwoodproducts.co.nz 5.0 ECOPLY® BARRIER COMPONENTS Table 1: Product Range Description Weight (kg/m2) Thickness Width Length Ecoply® Barrier – structural plywood with factory applied proprietary coating to sheet surface and edges Approx 4.0 7mm 1197mm 2440mm
Specification & Installation Guide June 2011
https://productselector.co.nz/media/files/ecoply-barrier-specification-installation-guide-june11.pdf
Where Ecoply® Barrier is used as structural bracing refer to the specifications detailed in Section 3.0: Structural Bracing in the Ecoply Specification and Installation Guide. 6.3 FASTENER DURABIlITy Ecoply Barrier is designed for use in sheltered conditions such as cavity construction and not as an external cladding. Fasteners shall
Got enough information about Ecoply Nz Bracing?
We hope that the information collected by our experts has provided answers to all your questions. Now let's race!