Interested in racing? We have collected a lot of interesting things about Ep2 Bracing. Follow the links and you will find all the information you need about Ep2 Bracing.
ECOPLY BRACING SPECIFICATIONS: EP2 - CHH Ply
https://chhply.co.nz/assets/Uploads/b244fc6694/Ecoply-Bracing-EP2-Specification-Tech-Note-April-2016.pdf
EP2 - Custom Protective Relay Control Panels and Drop in ...
Quality Wiring. Posted by EP² in EP² Blog on 7/3/2013. Expert craftsmanship and attention to detail ensure that EP2 panels are built and wired to meet and exceed the systematic guidelines of our rigorous Quality Assurance Process. AddThis.
Ecoply Bracing - EP2 Specification Apr-09
http://www.organonarchitecture.co.nz/CLIENTS/Bishop-Blackmore/ConsentDocs/Ecoply%20Bracing%20-%20EP2%20Specification%20(Aug-09).pdf
Ecoply Bracing - EP2 Specification Apr-09 Ecoply®Bracing Systems are designed to meet the requirements of the NZBC and have been tested and analysed using the P21 method referenced in NZS3604:1999 listed as an acceptable solution B1/AS1 Structure.
Civic 01/- 3dr EP2 1.4/1.6L Cold air intake ... - bracing.tech
https://www.bracing.tech/civic-01-3dr-ep2-1-4-1-6l-cold-air-intake-system
Civic 01/- 3dr EP2 1.4/1.6L Cold air intake system
Ecoply® Structural Square Edge » Plywood NZ
https://chhply.co.nz/ranges/ecoply/ecoply-structural-plywood/structural-square-edge/
Structural Square Edge. Ecoply ® Structural Square Edge plywood is structural-grade plywood with a range of uses throughout the building industry, particularly where known structural characteristics are required. It is available in a full range of thicknesses from 7mm to 25mm and in untreated and treated H3.2 CCA or H3.1 LOSP.
Civic 01/- EP2 1.6L Sport 3drs HB Cat-back exhaust G200
https://www.bracing.tech/civic-01-ep2-1-6l-sport-3drs-hb-cat-back-exhaust-g200
ECOPLY SPECIFICATION & INSTALLATION GUIDE
https://tropex.co.nz/sites/default/files/product_pdfs/Ecoply%20Specification%20Installation%20Guide.pdf
Structural bracing and ceiling diaphragms 3.0 Roofs and decks 4.0 Flooring 5.0 Note: Technical notes referenced in this guide can be downloaded from www.chhwoodproducts.co.nz or contact Carter Holt Harvey Woodproducts on 0800 326 759. Table 1: Ecoply® Product Range Nominal Thickness (mm) 7 9 12 15 17 19 21 25 Sheet length (x 1200 mm width)
BARRIER Specification Minimum Wall Lining Requirements …
https://ecoplybarrier.co.nz/assets/Uploads/201403-CHH-Ecoply-Barrier-EPBTechnicalNote-v1.00.pdf
BRACING SPECIFICATION: EPB1 SINGLE SIDED STRUCTURAL PLYWOOD BRACE Specification No. Minimum Wall Length Lining Requirements BUs/m Wind BUs/m Earthquake EPB1_0.4 0.4 m 7 mm Ecoply® Barrier one side 80 95 EPB1_0.6 0.6 m 7 mm Ecoply Barrier one side 95 105 EPB1_1.2 1.2 m 7 mm Ecoply Barrier one side 120 135 FRAMING Wall framing must comply with:
Ecoply Bracing Specification EP1
http://www.organonarchitecture.co.nz/CLIENTS/Bishop-Blackmore/ConsentDocs/Ecoply%20Bracing%20-%20EP1%20Specification%20(Apr-09).pdf
The brace element may be fixed over cavity battens. The cavity battens must be a minimum of 40 x 20mm nailed staggered formation at 150mm centres to studs around the perimeter of the brace element, and nailed to the intermediate studs within the element at 300mm centres, with 50mm x 2.8mm flat head galvanised or annular grooved stainless steel
BARRIER
https://www.ecoplybarrier.co.nz/assets/Uploads/2017-CHH-EcoplyBarrier-SpecificationAndInstallationGuide-v1.01-Web.pdf
• ®Bracing Hold-Down Connectors: GIB HandiBrac hold-down brackets manufactured by MiTek® complete with mechanical fastener with a minimum 15kN uplift capacity for concrete floors and 150mm x 12mm galvanised coach screw for timber floors. • Fasteners. 5.1 TAPES The Ecoply Barrier – Sill Tape, Frame Sealing Tape and Sealing
Got enough information about Ep2 Bracing?
We hope that the information collected by our experts has provided answers to all your questions. Now let's race!