§2395.79. Equipment Bonding Jumpers. - California …

    https://www.dir.ca.gov/Title8/2395_79.html
    none

Equipment Grounding Conductor on the outside of a raceway?

    https://forums.mikeholt.com/threads/equipment-grounding-conductor-on-the-outside-of-a-raceway.89620/
    petersonra. The NEC limits the bonding jumper to 6ft (with and exception for a pole top bond). 300.3 (B) requires all conductors to be grouped together - the further apart the circuit conductors are, the greater the impedance as the magnetic fields don't cancel. The NEC doesn't tell you the why, only the how.

Outside Raceway or Enclosure | UpCodes

    https://up.codes/s/outside-raceway-or-enclosure
    Where installed outside of a raceway or enclosure, the length of the bonding jumper or conductor or equipment bonding jumper shall not exceed 6 feet (1829 mm) and shall be routed with the raceway or enclosure. [250.102 (E) (2)] Equipment bonding jumpers and supply-side bonding jumpers installed for bonding grounding electrodes and installed at outdoor pole locations for …

Where an equipment bonding jumper is installed on the …

    https://www.chegg.com/homework-help/equipment-bonding-jumper-installed-outside-raceway-length-sh-chapter-u5-problem-18ct-solution-9781337101974-exc
    Where an equipment bonding jumper is installed on the outside of a raceway, the length shall not exceed _____ ft and shall be routed with the raceway or enclosure. Step-by-step solution This problem hasn’t been solved yet!

Grounding and Bonding — Part 1 of 3 - EC&M

    https://www.ecmweb.com/national-electrical-code/code-basics/article/20897016/grounding-and-bonding-part-1-of-3
    If you use a single equipment bonding jumper to bond two or more raceways, size it per 250.122, based on the rating of the largest circuit overcurrent device. You can install equipment bonding jumpers, bonding jumpers, or bonding conductors inside or outside of a raceway. If inside a raceway, these conductors must be identified per 250.119.

Grounding & Bonding Lvl 2, Lesson 4 Flashcards

    https://www.chegg.com/flashcards/grounding-bonding-lvl-2-lesson-4-9cb55ab7-839b-48dc-8bd0-00f06e949051/deck
    Where flexible metal conduit or liquidtight flexible metal conduit is installed in a hazardous (classified) location, an equipment bonding jumper is required to be installed either on the inside or on the outside of the conduit and the conduit cannot serve as an equipment bonding jumper or equipment grounding conductor even if the conditions in 250.118(5) and (6) are satisfied.

NEC practice exam Flashcards | Quizlet

    https://quizlet.com/691593557/nec-practice-exam-flash-cards/
    at least 20 ft of ½ in. or larger steel reinforcing bars or rods. 250.52 (A) (3) An equipment bonding jumper can be installed on the outside of a raceway, providing the length of the equipment bonding jumper is not more than _____ and the equipment bonding jumper is …

Final Review 3 Flashcards | Quizlet

    https://quizlet.com/307403289/final-review-3-flash-cards/
    Where an equipment bonding jumper is installed on the outside of a raceway, the length shall not exceed _____ feet and shall be routed with the raceway or enclosure. 6 A surface-mounted incandescent luminaire installed on the ceiling of a clothes closet must have a minimum clearance of ___________ inches between the luminaire and the nearest ...

Article 250 Grounding and Bonding (continued)

    http://garyklinka.com/necquiz102.htm
    An equipment bonding jumper must be used to connect the grounding terminal of a grounding-type receptacle to a grounded box. Where the box is surface-mounted, direct metal-to-metal contact between the device yoke and the box can be permitted to …

Bonding Conductors and Jumpers | UpCodes

    https://up.codes/s/bonding-conductors-and-jumpers
    Exception: An equipment bonding jumper or supply-side bonding jumper longer than 1.8 m (6 ...