§2395.79. Equipment Bonding Jumpers. - California …

    https://www.dir.ca.gov/Title8/2395_79.html
    (c) Installation. The equipment bonding jumper shall be permitted to be installed inside or outside of a raceway or enclosure. Where installed on the outside, the length of the equipment bonding jumper shall not exceed six (6) feet and shall be routed with the raceway or enclosure. (Title 24, Part 3, Section 250-79(a), (b) and (e).)

Equipment Grounding Conductor on the outside of a raceway?

    https://forums.mikeholt.com/threads/equipment-grounding-conductor-on-the-outside-of-a-raceway.89620/
    petersonra. The NEC limits the bonding jumper to 6ft (with and exception for a pole top bond). 300.3 (B) requires all conductors to be grouped together - the further apart the circuit conductors are, the greater the impedance as the magnetic fields don't cancel. The NEC doesn't tell you the why, only the how.

Bonding Conductors and Jumpers | UpCodes

    https://up.codes/s/bonding-conductors-and-jumpers
    Exception: An equipment bonding jumper or supply-side bonding jumper longer than 1.8 m (6 ft) shall be permitted at outside pole locations for the purpose of bonding or grounding isolated sections of metal raceways or elbows in stalled in exposed risers of metal conduit or other metal raceway, and for bonding grounding electrodes, and shall not ...

Outside Raceway or Enclosure | UpCodes

    https://up.codes/s/outside-raceway-or-enclosure
    E3908.20.2 Outside Raceway or Enclosure. Where installed outside of a raceway or enclosure, the length of the bonding jumper or conductor or equipment bonding jumper shall not exceed 6 feet (1829 mm) and shall be routed with the raceway or enclosure. [250.102 (E) (2)] Equipment bonding jumpers and supply-side bonding jumpers installed for ...

Service & Main Bonding Jumpers - IAEI Magazine

    https://iaeimagazine.org/1998/98november/service-main-bonding-jumpers/
    The main bonding jumper is one of the most critical elements in the safety grounding system. This conductor is the link between the grounded service conductor, the equipment grounding conductor and in some cases, the grounding electrode conductor. The primary purpose of the main bonding jumper is to carry the ground-fault current from the …

Grounding and Bonding — Part 1 of 3 - EC&M

    https://www.ecmweb.com/national-electrical-code/code-basics/article/20897016/grounding-and-bonding-part-1-of-3
    The NEC now clarifies that bonding jumpers on the load side of an overcurrent device must comply with all of Sec. 250.122, not just Table 250.122. It also: Clarifies the rules for bonding jumpers installed in a raceway versus those installed outside a raceway. Adds provisions for protecting aluminum bonding jumpers against corrosion.

CODE GUIDE - EC&M

    https://www.ecmweb.com/cee-news-magazine-archive/article/20894736/code-guide
    Equipment-bonding jumper Q In the 2002 NEC Section 350.60 Grounding and Bonding, the title of Section 351.9 of the 1999 Code has been changed by adding ..and Bonding and the Section re-identified as 350.60. The 2002 NEC Section 250.118 Types of Equipment Grounding Conductors paragraph (7)c indicates that the Code does not consider the liquidtight …

Grounding level 1 Flashcards - Quizlet

    https://quizlet.com/493056235/grounding-level-1-flash-cards/
    An equipment bonding jumper is permitted to be installed either inside or outside of a raceway or enclosure. true. When an equipment bonding jumper is installed on the outside of flexible metal conduit or liquidtight flexible metal conduit, the length of the jumper is generally limited to not exceeding ? in length. ... Cable trays are permitted ...

NEC practice exam Flashcards | Quizlet

    https://quizlet.com/691593557/nec-practice-exam-flash-cards/
    250.52 (A) (3) An equipment bonding jumper can be installed on the outside of a raceway, providing the length of the equipment bonding jumper is not more than _____ and the equipment bonding jumper is routed with the raceway. 72 in. 250.102 …

Article 250 Grounding and Bonding (continued)

    http://garyklinka.com/necquiz102.htm
    250.146. 34. An equipment bonding jumper must be used to connect the grounding terminal of a grounding-type receptacle to a grounded box. Where the box is surface-mounted, direct metal-to-metal contact between the device yoke and the box can be …