What Is Pipeline And Hvac Air Duct Seismic Bracing System

    https://www.metmac.com/what-is-pipeline-and-hvac-air-duct-seismic-bracing-system.html#:~:text=Seismic%20bracing%20is%20a%20seismic%20support%20system%20with,structure%20when%20encountering%20an%20earthquake%20of%20fortified%20intensity.
    none

Flammable Gas Piping- Seismic Considerations - Risk Logic

    https://risklogic.com/seismic-considerations-for-flammable-gas-piping/
    Install a seismic gas shutoff valve at the supply side to each individual building utilizing fuel gas with pressures at or below 60 psi. Fuel gases include methane (natural gas), propane and butane. Locate this valve outside buildings, downstream of the pressure regulator, and in a clearly marked and accessible location, in accordance with the manufacturer’s instructions.

Seismic Bracing for Ductwork, HVAC, Electrical & Pipe

    https://blog.qrfs.com/329-seismic-bracing-for-ductwork-hvac-electrical-systems/
    none

Seismic Bracing Systems - unistrutohio.com

    https://www.unistrutohio.com/wp-content/uploads/pdf/library/unistrut-seismic-bracing-for-1998-cbc.pdf
    Design a brace for a single pipe hanger with 8” diameter pipe and hangers spaced at maximum distance (see figure E-1). FIGURE E-1 Solution: Step 1 Select hanger type (page 3-6, 3-7, 3-8, 3-9, 3-10) given the pipe diameter of 8". Step 2 Determine the maximum hanger spacing, to be 19 ft. on center (page 2-1, table 1).

Seismic Bracing | Power-Strut

    https://www.power-strut.com/products/seismic-bracing
    OSHPD OPM-0294-13. Power-Strut is a global leader in seismic bracing and we have supported the industry for decades. We have recently acquired an OPM pre-approval from OSHPD and you may find those pre-approved values and pages …

Seismic Bracing | Mason Industries

    https://mason-ind.com/seismic-bracing/
    SEISMIC BRACING. Seismic Cable Restraints shall consist of galvanized steel aircraft cables sized to resist seismic loads with a minimum safety factor of …

Seismic Protection for Pressure Piping Systems - ASME

    https://www.asme.org/topics-resources/content/seismic-protection-for-pressure-piping-systems
    Longitudinal Bracing. Proper seismic detailing for suspended pipes requires both transverse and longitudinal braces, installed at spacing intervals that depending primarily on the level of seismic activity at the building site, location within the building, pipe size and type, and the strength of the connections to the structure.

Unistrut Seismic Bracing Systems

    https://www.unistrutohio.com/wp-content/uploads/pdf/library/unistrut-seismic-bracing-systems.pdf
    starting the installation of the seismic bracing system. The Seismic Tables defined in Pages 2-8 & 2-9 are for a seismic factor of 1.0g and can be used to determine brace location, sizes, and anchorage of pipe/duct/conduit and trapeze supports. The development of a new seismic table is required for seismic factors other than 1.0g and must be reviewed by OSHPD prior to seismic …

Natural Gas Pipe Seismically Exempt? - Eng-Tips

    https://www.eng-tips.com/viewthread.cfm?qid=243382
    Natural Gas Pipe Seismically Exempt? greggriffin (Mechanical) (OP) 22 Apr 09 15:36 Is a natural gas pipe inside/outside a building allowed to be exempt from seismic bracing if it is less than 2-1/2" in interior diameter and/or mounted less than 12" from top of pipe to supporting structure? Replies continue below Recommended for you

TOLCO seismic bracing - Eaton

    https://www.eaton.com/content/dam/eaton/products/support-systems/tolco-seismic-bracing/seismic-bracing-ul-fm-approved-fire-sprinkler-systems-flyer-sa309005en.pdf
    “Tops of risers exceeding 3 feet (1m) in length shall be provided with a four way brace.” Lateral seismic brace assemblies NFPA 13 (2013) Sec. 9.3.5.5 “Lateral sway bracing shall be provided on all feed and cross mains regardless of size and all branch lines and other piping with a diameter of 21/2 inches (65mm) or larger.”*

INSTALLING SEISMIC RESTRAINTS FOR DUCT AND …

    https://mitigation.eeri.org/files/installing_seismic_restraints_ducts_pipes.pdf
    design the seismic bracing. This manual is required to be on the job site. Refer to approved construction documents that show the overall layout of the duct and pipe runs throughout the building. Normal vertical supports are provided at intervals as defined in codes and standards. Additional seismic bracing may be required.