Heat Tracing Fire Sprinkler Systems: When, Where, and How

    https://blog.qrfs.com/157-heat-tracing-fire-sprinkler-systems-when-where-and-how/
    Heat tracing is a viable freeze-protection solution for some wet sprinkler systems. Heat tracing installed within NFPA parameters can protect sections of pipe in wet fire sprinklers from freezing, providing a viable alternative to antifreeze or installing or retrofitting more complex and expensive dry pipe or preaction systems. That said, it does have its limitations, in both how …

Can you heat trace sprinkler pipe?

    https://findanyanswer.com/can-you-heat-trace-sprinkler-pipe
    Heat tracing, also known as heat tape, is an option to protect fire sprinkler pipe from freezing. They are also less complex to install and maintain than preaction or dry pipe sprinkler systems, where the delivery of water in a fire can be delayed up to 60 seconds.

UL Certified Trace Heating Equipment for Fire Sprinkler …

    https://www.ul.com/news/ul-certified-trace-heating-equipment-fire-sprinkler-pipes
    UL’s certification of trace heating for fire sprinkler systems includes the application of requirements from the 2012 edition of IEEE 515.1 that are relevant to sprinkler systems along with additional requirements described …

Heat trace systems for wet-pipe fire sprinkler systems

    https://www.chromalox.com/-/media/files/whitepapers/en-us/wp-heattraceforfiresprinklersystems.pdf
    in a wet-pipe fire sprinkler system are due to the inability to insulate sprinkler heads and other exposed system components. Concentrated heat tracing along these exposed sections of the fire suppression systems can lead to temperature spikes that have been known to trigger false alarms. To address challenges with irregular temperature profiles,

Heat Tracing Systems for Fire Sprinklers – System is the ...

    https://blog.nvent.com/heat-tracing-systems-for-fire-sprinklers-system-is-the-critical-word/
    In 2019, Underwriters Laboratories (UL) issued the first certification for trace heating equipment for use with a fire sprinkler system, including the installation on sprinkler branch lines. This certification complements the requirements in the NFPA 13, Standard for Installation of Sprinkler Systems. Certification for heat tracing systems for fire sprinklers …

Fire Sprinkler Freeze Protection - Regulations and System ...

    https://www.libertyelectricproducts.com/heat-trace-cable/fire-sprinkler-freeze-protection.html
    The electric heat trace systems for fire sprinkler freeze protection that we design, and supply are listed and approved. The approval is for the latest NFPA 13, IEEE 515.1 and UL 515A for installation of heat cable on wet fire sprinkler piping. The excerpt from the NFPA 2019 regulations that pertains specifically to freeze protection is listed below.

FIRE SPRINKLER SYSTEM FREEZE PROTECTION — XL-TRACE …

    https://raychem.nvent.com/sites/g/files/hdkjer246/files/acquiadam/2020-08/RAYCHEM-DG-H58489-XLTraceFS-EN.pdf
    heat tracing to freeze protect fire suppression systems including supply lines, standpipes and branch lines containing sprinklers. XL-Trace system is c-CSA-us certified for use on fire suppression systems under CSA C22.2 No. 130-03 using nVent RAYCHEM C910-485 and ACS30 control systems. 5XL and 8XL heating

Heat trace systems for wet-pipe fire sprinkler systems ...

    https://insights.globalspec.com/article/11856/heat-trace-systems-for-wet-pipe-fire-sprinkler-systems
    Heat trace systems for wet-pipe fire sprinkler systems. Figure 1. Sprinkler systems in cold environments require freeze protection systems. Source: Chromalox Chromalox’s fire sprinkler pipe freeze protection system addresses operability, code approval, cost and installation approved to current NFPA 13, IEEE 515.1 and UL 515A standards for testing, design, …

Pipe Heat Trace | Heat Trace Cable | nVent

    https://raychem.nvent.com/en-us/solutions/commercial/applications/pipe-freeze-protection
    nVent RAYCHEM electric heat trace cables for water lines prevents water in pipes, pumps and other equipment from freezing. Our self-regulating heat trace cable provides heat where it’s needed, without the added worry of overheating. Our comprehensive range of electrical heat trace cables are versatile enough to be used in a wide range of commercial and industrial buildings.

Fire Sprinkler Freeze Protection Specification - Heat Trace

    https://raychem.nvent.com/sites/g/files/hdkjer246/files/acquiadam/2020-03/RAYCHEM-ES-H59095-PFPFireSprinkler_XLTraceSpec-EN.doc
    The complete heat trace system (heating cable, connection kits, and controller) shall be listed by a Nationally Recognized Testing (NRTL), and marked for intended use of freeze protection of standpipes, mains and branch fire sprinkler piping. [Option …