Chase nipple | Mike Holt's Forum
https://forums.mikeholt.com/threads/chase-nipple.103041/
Chase nipples are listed as fittings, not raceways. don_resqcapt19 Moderator Staff member Location Illinois Occupation retired electrician Apr 9, 2013 #6 mjf said: I would think it is a tubing nipple not exceeding 24" Tubing is not threaded. kwired …
chase nipple | Electrician Talk
https://www.electriciantalk.com/threads/chase-nipple.59676/
Yes, under chase nipples it says to go to conduit fittings but they don't mention chase nipple (that name) in that section. I will add that some of the cmp members still consider the fitting to follow the rules of raceways for fill etc. If I install 5 18" nipples together I will have a 90" section of raceway and it is required to follow the rules.
Chase nipples | Mike Holt's Forum
https://forums.mikeholt.com/threads/chase-nipples.115760/
Used 3-2" chase nipples to feed branch circuits. Used center chase nipple for about 15 neutrals because of proximity to neutral bar. AHJ said I need to splice neutrals and pull them through with other conductors. 300.3 B applies if a chase nipple is considered and raceway. Wondering how it falls in application. infinity Moderator Staff member
Chase Nipples - Lumen
https://www.lumen.ca/en/products/11-conduit-raceway-strut/03-conduit-fittings/02-metallic-conduit-fittings/12-rigid-conduit-fittings/10-nipples/01-chase-nipples
Chase Nipple 17 Insulated Chase Nipple 8 Non-Insulated Chase Nipple 6 Chase Conduit Nipple 5. Thread Length. 16.51 mm 2 24.38 mm 2 8.63 mm 2 1-1/16 in 1 1-13/64 in 1 1-23/64 in 1 1-3/64 in 1 1-5/16 in 1 1-5/64 in 1 13.49 mm 1. 13/16 in 1 15 mm 1 17/32 in 1 19.05 mm 1 19.83 mm 1 21/32 in 1 29.97 mm 1 29/64 in 1 33/64 in 1 35/64 in 1 5/8 in 1 57 ...
bonding chase nipple | Mike Holt's Forum
https://forums.mikeholt.com/threads/bonding-chase-nipple.51306/
even though the chase nipple is in direct metal to metal contact with both enclosures it still needs it because a regular lockring isn't an approved means or ??? It is a raceway and it contains service conductors. It is required to be bonded. They do make bonding bushings that can be installed after the cables are in place but they are not cheap.
Nipple definition - Mike Holt's Forum
https://forums.mikeholt.com/threads/nipple-definition.64588/
A nipple is really just a raceway. Where nipple would be used the code should say "raceway of blah blah length" and bends should not matter.... length is length chris kennedy Senior Member Location Miami Fla. Occupation 60 yr old tool twisting electrician Jun 13, 2009 #3 Vertex said:
Conduit & Raceway Fittings Conduit Nipples Chase Nipple | Frost …
https://www.frostelectric.com/catalog/products/Conduit-Raceway-Fittings/Conduit-Nipples/Chase-Nipple/dept-5VU
The Chase Nipple along with a rigid coupling is used to terminate a run of threaded conduit into an enclosure box. The Chase Nipple is rated for both indoor and outdoor use. It is UL and CSA listed. It is usable indoors or outdoors.
Halex 1/2 in. Rigid Conduit Chase Nipples (100-Pack) 07005B
https://www.homedepot.com/p/1-2-in-Rigid-Conduit-Chase-Nipples-100-Pack-07005B/202241109
Terminate threaded conduit or provide a short raceway with the 1/2 in. Rigid Conduit Chase Nipples (100-Pack). These chase nipples are made of die-cast zinc and are ideal for use indoors or outdoors. These chase nipples meet UL and CSA requirements. Use with a rigid coupling to terminate threaded conduit to a knockout box or enclosure
Knowledge Beats Experience - Electrical Contractor Magazine
https://www.ecmag.com/section/codes-standards/knowledge-beats-experience
The fill area for a nipple is not the same as a raceway. The 60 percent fill area for a nipple allows more conductors to occupy the conduit than the 40 percent fill area allotted for a raceway without the application of derating factors. Sleeves A sleeve is used when a cord, cable or raceway requires protection from physical damage.
3/4 Inch Chase Nipple, Malleable Iron for Use with Rigid/IMC Conduit
https://www.crescentelectric.com/conduit-raceway-and-strut/conduit-fittings/electrical-conduit-nipple/34-inch-chase-nipple-malleable-iron-for-use-with-rigidimc-conduit
Show Compared Products north. Thomas & Betts. 3/4 Inch Chase Nipple, Malleable Iron for Use with Rigid/IMC Conduit. MFR #: 843-TB. UPC: 786210008431. Item #: 173739. Thomas & Betts.