Supporting Pull Boxes on Raceways | Mike Holt's Forum
https://forums.mikeholt.com/threads/supporting-pull-boxes-on-raceways.2552297/#:~:text=Junction%20or%20pull%20boxes%20are%20not%20designed%20to,hubs%20are%20not%20condulets%2C%20they%20are%20junction%20boxes.
Pull Box Vs Junction Box: A Detailed Guide - E-Abel
https://www.eabel.com/pull-box-vs-junction-box/
Only conductors are pulled and fed into a raceway system through these locations. They must be used in conduit lines when the number of bends connecting outlets surpasses the National Electric Code’s maximum number. The size of a pull box is determined by the size and amount of conductors, as well as the quantity and diameter of raceways.
Raceway Restrictions in a Pull Box - EC&M
https://www.ecmweb.com/code-quiz-of-day/article/20898747/raceway-restrictions-in-a-pull-box
The correct answer is: a) six. The rules for pull and junction boxes, as well as conduit bodies, are outlined in Sec. 314.28 of the 2011 NEC. As noted in the first sentence of 314.28 (A) (2), "Where splices or where angle or U pulls are made, the distance betwwen each raceway entry inside the box or conduit body and the opposite wall of the box or conduit body …
Supporting Pull Boxes on Raceways | Mike Holt's Forum
https://forums.mikeholt.com/threads/supporting-pull-boxes-on-raceways.2552297/
Junction or pull boxes are not designed to be part of a conduit raceway system and need to be supported to prevent bowing or sagging. Cast boxes with threaded hubs are not condulets, they are junction boxes. kwired Electron manager Location NE Nebraska Mar 11, 2020 #12 jeremy.zinkofsky said:
Pull and Junction Boxes - Electrical Contractor Magazine
https://www.ecmag.com/section/codes-standards/article-370-pull-and-junction-boxes-0
Boxes containing raceways on opposite walls, regardless of the offset, qualify as straight pulls. Computing the minimum dimensions of a box containing straight pull (s) is an easy calculation—simply multiply the largest raceway (trade diameter) by eight. For example, calculate the minimum dimension for a pull box with two 2-inch conduits.
Taking the Mystery Out of Sizing Pull Boxes and Junction Boxes
https://www.ecmweb.com/national-electrical-code/code-basics/article/21234199/taking-the-mystery-out-of-sizing-pull-boxes-and-junction-boxes
A pull box contains a trade size 2 and trade size 3 raceway on the left side, a trade size 3 raceway on the top, and a trade size 2 raceway on the right side. The trade size 2 raceways are a straight pull, and the trade size 3 raceways are an angle pull. What’s the horizontal dimension of this box? Solution: Left to right straight pull = 8 × 2 in. = 16 in.
Understanding Raceways - EC&M
https://www.ecmweb.com/national-electrical-code/code-basics/article/20903368/understanding-raceways
The NEC defines a raceway as: “An enclosed channel designed expressly for holding wires, cables, or bus bars, with additional functions as permitted in this Code [Art. 100].” Common rules. These rules apply to all types of raceway: • The total amount of bends (including offsets) between pull points can’t exceed 360°.
Pull and Junction Box Calculations - Electrical Contractor Magazine
https://www.ecmag.com/section/codes-standards/pull-and-junction-box-calculations
Boxes containing raceways on opposite walls, regardless of where they are located or the amount of offset, qualify as straight pulls (see Figure 4). Calculating the minimum dimensions of a box containing straight pull (s) is quite simple: multiply the trade size (metric designator) of the largest raceway by eight.
Pull and Junction Boxes - Electrical Contractor Magazine
https://www.ecmag.com/section/codes-standards/article-370-pull-and-junction-boxes-1
For raceways containing conductors of No. 4 or larger, and for cables containing conductors of No. 4 of larger, the minimum dimensions of pull or junction boxes installed in a raceway or cable run must comply with Section 370-28 (a) (1) through (3). This section provides requirements for pull and junction boxes used on systems 600 volts, nominal, or less to ground.
wireways used as pull box | Mike Holt's Forum
https://forums.mikeholt.com/threads/wireways-used-as-pull-box.110207/
As far as I know that is not a defined term. plumb bob Member Feb 14, 2014 #4 I would consider it a pull box and subject to sizing restrictions if the raceway system into which it is installed would exceed 360 degrees of bending without it edit: or any time the wire does not pass strait thru the wireway, using it as a ninety degree turn for example
Is a Junction Box a Raceway? | Mike Holt's Forum
https://forums.mikeholt.com/threads/is-a-junction-box-a-raceway.2543554/
One interpretation is that the junction box is not considered a raceway and the free air rating of 405A is applicable for each of the 90C RHW-2 with its 90C rated terminations. Others do consider the junction box a raceway, with each RHW-2 only good for 260A. A third opinion is that the raceway vs not a raceway question is irrelevant based on ...