NFPA 13 Seismic Bracing Requirements: Cable Sway Braces
https://blog.qrfs.com/320-nfpa-13-seismic-bracing-requirements/
Seismic Bracing and Calculations
https://www.kamal-mech-engr.com/seismic-bracing-calculations
The specific variation of this formula for calculating seismic loads is found in section 18.5.9.3 of NFPA 13: Fpw = Cp x Wp Where … Wp is the weight of the water-filled pipes multiplied by 1.15, Cp is the seismic coefficient, and Fpw is the horizontal force Calculating weight for …
Loos Engineers' Tools - NFPA-13 Seismic Bracing …
https://tools.loosseismicbracing.com/
The Loos & Co. Web-based Trade Calculation Tools make it easier than ever to fill out the NFPA-13 Seismic Bracing Calculation form. This calculator guides the user step by step to create and save designs for multiple projects. Necessary …
Introduction to Seismic Protection for Sprinkler Systems
https://www.nfpa.org/News-and-Research/Publications-and-media/Blogs-Landing-Page/NFPA-Today/Blog-Posts/2021/03/19/Introduction-to-Seismic-Protection-for-Sprinkler-Systems
NFPA 13 contains requirements for both lateral (perpendicular to the piping) and longitudinal (parallel to the piping) horizontal braces (shown below). The maximum spacing of lateral braces of 40 ft (12 m) is based on the strength of the piping as a beam under the uniform load of its expected horizontal “weight.”
EarthquakeBrace.com - Publishers of the Manual of …
http://earthquakebrace.com/nfpacalc.html
Do NFPA-13 Seismic Bracing Calculations ON LINE using the NFPA-13 Calculation Form. In minutes you will enter project and calculation criteria in 4 easy steps. The result is a completed NFPA-13 Seismic Bracing Calculation …
NFPA 13 Standard for the Installation of Sprinkler …
https://www.nfpa.org/assets/files/AboutTheCodes/13/TIA13-02-1.pdf
A 9.3.5.6.1 The several factors used in the computation of the horizontal seismic load should be available from the project architect or structural engineer. Sprinkler systems are emergency systems and as such should be designed for an Importance Factor (Ip) of 1.5. Seismic load equations allow the reduction of the seismic force by a Component