NFPA 13 Seismic Bracing Requirements: Cable Sway …
https://blog.qrfs.com/320-nfpa-13-seismic-bracing-requirements/
NFPA 13 gives requirements for the placement of lateral braces and longitudinal braces on main lines, for the bracing of changes of direction of main lines, for the bracing of risers, and for the bracing of seismic separation assemblies ( see our article on flexible design for more information on these elements ).
NFPA 13 Standard for the Installation of Sprinkler …
https://www.nfpa.org/assets/files/AboutTheCodes/13/TIA13-02-1.pdf
9.3.5.7 Where the horizontal seismic loads used exceed 0.5 Wp and the brace angle is less than 45 degrees from vertical or where the horizontal seismic load exceeds 1.0 Wp and the brace angle is less than 60 degrees from vertical, the braces shall be arranged to resist the net vertical reaction produced by the horizontal load.
Introduction to Seismic Protection for Sprinkler Systems
https://www.nfpa.org/News-and-Research/Publications-and-media/Blogs-Landing-Page/NFPA-Today/Blog-Posts/2021/03/19/Introduction-to-Seismic-Protection-for-Sprinkler-Systems
A sprinkler system installed in a building that is subject to seismic activity may require seismic bracing by the local or state building code . If required, Chapter 18 of NFPA 13 outlines requirements for the seismic bracing, which includes bracing, flexible connections, pipe clearance to structural members, pipe restraint, and restrictions on the types of hangers and …
Chapter 18: Installation Requirements for Seismic Protection, …
https://up.codes/viewer/austin/nfpa-13-2019/chapter/18/installation-requirements-for-seismic-protection
The seismic separation assembly shall include a four-way brace upstream and downstream within 6 ft (1.8 m) of the seismic separation assembly. 18.3.4 Bracing shall not be attached to the seismic separation assembly. 18.4* Clearance 18.4.1*
Chapter 9 Hanging, Bracing, and Restraint of System Piping
https://up.codes/viewer/colorado/nfpa-13-2013/chapter/9/hanging-bracing-and-restraint-of-system-piping
The seismic separation assembly shall include a four-way brace upstream and downstream within 6 ft (1.8 m) of the seismic separation assembly. 9.3.3.4 Bracing shall not be attached to the seismic separation assembly .
Seismic Restraint of Sprinkler Systems – NFPA-13 versus …
https://risklogic.com/seismic-restraint-of-sprinkler-systems-nfpa-13-versus-fm-global-standards/
NFPA-13 does not specify when seismic bracing is required, just how to install it when it is required. FM Global specifies seismic bracing be provided when located in 50-year through 500-year earthquake zones, as shown on the maps in FM Global Data Sheet 1-2, Earthquakes.
How to Determine if Sprinklers Require Seismic? - MeyerFire
https://www.meyerfire.com/blog/how-to-determine-if-sprinklers-require-seismic
ASCE 7 Chapter 13 suggests that seismic bracing is required for all structures, unless they meet an exemption. Section 13.1.4 specifically lists exemptions from seismic design requirements. These Exemptions include: Mechanical and electrical components in Seismic Design Category B.
Seismic Bracing - NFPA (fire) Code Issues - Eng-Tips
https://www.eng-tips.com/viewthread.cfm?qid=232816
You must follow NFPA 13 rules for 13R installations. You will use the Ss (0.2) spectral accelleration value, and obtain it from the USGS web site based on latitude and longitude coordinates of the site. As far as the specifics of the seismic bracing referred to in IBC 2006, you may have missed it, but the reference document is ASCE 7, 2005 edition.
Eliminating the Confusion from Seismic Codes and …
https://www.bicsi.org/uploadedfiles/PDFs/conference/2019/fall/PRECON_3C.pdf
Member NFPA 13 Committee on Hanging and Bracing Member UL 203 STP for Listing of Hangers and Seismic Braces & Daniel J. Duggan ... • ASCE 7-10 Chapter 13 Seismic Design Requirements for Nonstructural Components • 2016 • E.O. (Executive Order) 13717 • …