    https://criticalcarenow.com/pa-catheter-basics/
    none

Pulmonary Artery Catheter • LITFL • CCC equipment

    https://litfl.com/pulmonary-artery-catheter/
    Lumens. blue = right atrial lumen = proximal injectate port -> terminates 30cm from the tip of the catheter lies within the right atrium when the tip of the catheter is in the pulmonary artery. This port can monitor RA pressures (RAP/ CVP) and receive the injectate for cardiac output studies. Can also be used to give fluids and drugs.

Pulmonary Artery Catheter Learning Package

    https://aci.health.nsw.gov.au/__data/assets/pdf_file/0004/306589/Pulmonary_Catheter_Learning_Package.pdf
    The pulmonary artery catheter (PAC) is a balloon tipped thermo dilution catheter 110cms long, that is inserted via a large vein and floated into the pulmonary artery. It is used to obtain haemodynamic measurements which together with clinical observations indicate how efficiently the heart is functioning. The PAC directly measures:

Pulmonary Artery Catheterization | Johns Hopkins Medicine

    https://www.hopkinsmedicine.org/health/treatment-tests-and-therapies/pulmonary-artery-catheterization
    Pulmonary artery catheterization is a procedure using a long, thin tube called a catheter inserted into a pulmonary artery. It can help diagnose and manage a wide variety of health problems. The pulmonary arteries are the two major arteries coming from the right ventricle of the heart.

Pulmonary artery catheterization: Interpretation of

    https://www.uptodate.com/contents/pulmonary-artery-catheterization-interpretation-of-hemodynamic-values-and-waveforms-in-adults#!
    The pulmonary artery catheter (PAC; Swan-Ganz or right heart catheter) can be used for a variety of clinical purposes. Interpreting hemodynamic data from PACs is important for the diagnosis and management of a range of conditions including shock and pulmonary artery hypertension ( table 1 ).

2: The nuts and bolts of right heart catheterization and …

    https://thoracickey.com/2-the-nuts-and-bolts-of-right-heart-catheterization-and-pa-catheter-placement/
    The PA catheter needs to be “zeroed” at the level of the RA. Minimize the length of pressure tubing, the number of stopcocks, and the number of connections. Avoid narrow tubing, as the smaller the diameter of the tubing, the more pressure damping that occurs. Eliminate any air bubbles in the pressure line. The proper pressure scale needs to be used

Hemodynamic Monitoring: Arterial and Pulmonary Artery …

    https://aneskey.com/hemodynamic-monitoring-arterial-and-pulmonary-artery-catheters/
    Once the catheter is advanced to the “wedged” position (PAOP), the balloon is deflated and the catheter adjusted until 1.25 to 1.5 mL of inflation is needed to produce the PAOP tracing. The balloon should only be inflated long enough to record a measurement in order to avoid rupture of the artery or infarction of the downstream segment of lung.

Pulmonary Artery Catheter Helpful Hints 2017

    http://www.gwicu.com/Assets/Nursing%20Protocols/Pulmonary%20Artery%20Catheter%20[Swan%20Ganz]%20%20Helpful%20Hints%202018.pdf
    5) Identify the markings on the Catheter This will identify the depth of catheter Each little line = 10 cm Each large line = 50 cm PA distal [yellow port] tip of catheter CVP Proximal [blue port] below 30cm mark VIP Port [White port] above 30 cm mark 6) Identify Insertion / position technique Select PA scales on the GE monitor during insertion to see larger waveform

Advanced Hemodynamic Monitoring Swan-Ganz Pulmonary …

    https://edwardsprod.blob.core.windows.net/media/Default/devices/monitoring/hemodynamic%20monitoring/swan-ganz_poster.pdf
    of tracing Catheter spontaneous wedging Wedge type tracing with balloon deflated Appropriate “a” and “v” waves noted Proper wedgeProper Wedge The advanced technology Swan-Ganz catheter, using the same functionality as the standard Swan-Ganz catheter, provides the ability to continuously monitor the balance between

Interpretation of Hemodynamic Waveforms | Anesthesia …

    https://aneskey.com/interpretation-of-hemodynamic-waveforms/
    Catheter “whip” in the pulmonary artery pressure (Ppa) tracing. Scale in millimeters of mercury. RIGHT ATRIAL PRESSURE Right atrial pressure (Pra) is measured from either the distal lumen of the CVC or the proximal port of the PAC. (The CVP and Pra are equivalent and the latter designation will be used in the remainder of this chapter).