250.122 (F) Size of Equipment Grounding Conductors. Conductor…
https://www.electricallicenserenewal.com/Electrical-Continuing-Education-Courses/NEC-Content.php?sectionID=270.0#:~:text=If%20conductors%20are%20installed%20in%20parallel%20in%20the,protective%20device%20for%20the%20feeder%20or%20branch%20circuit.
Conductors Connected in Parallel: Each Set Must Have the Same ...
https://www.ecmag.com/section/codes-standards/conductors-connected-parallel-each-set-must-have-same-electrical
All of the paralleled conductors in each phase, neutral or grounded set must be the same length and be made from the same conductor material. They must be the same circular mil area and have the same type of insulation. Finally, all parallel conductors must be terminated in the same manner. This ensures that each conductor in the parallel set will carry the same amount of …
parallel feeders in same raceway | Mike Holt's Forum
https://forums.mikeholt.com/threads/parallel-feeders-in-same-raceway.51510/
Jul 22, 2008. #1. I have an application which requires 2 sets of 250MCM parallel feeders at 480V. The contractor is wanting to run both of these feeders in the same conduit. I am trying to decide weather or not to let him run both in the same conduit but am not all that knowledgeable on what the effects of this will be.
366.20 Conductors Connected in Parallel.
https://www.electricallicenserenewal.com/Electrical-Continuing-Education-Courses/NEC-Content.php?sectionID=297.0
Using the same raceway type (nonmetallic or ferrous metal) for each parallel set of conductors ensures that electrical current is not transferred to the raceway through induction. In the 2017 NEC, additional code language was added to address proper grouping of parallel conductors inside an auxiliary gutter. Before the code change, the requirements for grouping of the parallel …
Can you run parallel conductors in the same conduit?
https://askinglot.com/can-you-run-parallel-conductors-in-the-same-conduit
The equipment grounding conductors for parallel runs do not have to meet the requirement of 310.4 that calls for a minimum 1/0 conductor size, because the equipment grounding conductors in each raceway are full size as required by 250.122. In respect to this, what does it mean to install conductors in parallel? Joining conductors in parallel is like having …