NFPA 13 Seismic Bracing Requirements: Cable Sway …
https://blog.qrfs.com/320-nfpa-13-seismic-bracing-requirements/
The max load that bracing cable can handle depends on the brace angle; the closer the brace is to vertical, the smaller the allowable load. Bracing cable is only permitted ( 18.5.4.2 ) when it’s listed for maximum loads, so the maximum allowable load for any bracing cable should be readily available from the vendor or manufacturer.
Seismic Bracing Requirements for Nonstructural …
https://seblog.strongtie.com/2015/08/seismic-bracing-requirements-for-nonstructural-components/
12 Inch Rule: When a distributed system such as conduit ducts or pipes are suspended from the structure with hangers less than 12 inches in …
Seismic Building Codes | FEMA.gov
https://www.fema.gov/emergency-managers/risk-management/earthquake/seismic-building-codes
Seismic retrofitting of a building must also include steps to better protect non-structural components (suspended ceilings, non-load-bearing walls and utility systems) and building contents (furnishings, supplies, inventory and …
Seismic Bracing for Ductwork, HVAC, Electrical & Pipe
https://blog.qrfs.com/329-seismic-bracing-for-ductwork-hvac-electrical-systems/
Non-Structural Seismic Bracing | Office of Environment, …
https://ehs.berkeley.edu/workplace-safety/non-structural-seismic-bracing
The Q-BRACE program provides guidance to campus departments to address non-structural seismic safety hazards. Bracing Guidelines. These guidelines provide directions for proper restraint of common building contents in typical spaces on the UC Berkeley campus. The individual detail sheets below are designed to cover common contents in each kind ...
Seismic Bracing and Calculations
https://www.kamal-mech-engr.com/seismic-bracing-calculations
NFPA 13 requires seismic bracing for fire sprinkler risers, main lines, and branch lines 2.5 inches or larger. Pipe smaller than these areas is generally more flexible and requires only vertical restraint rather than bracing. The principles of Seismic Bracing Seismic bracing resists …
Introduction to Seismic Protection for Sprinkler Systems
https://www.nfpa.org/News-and-Research/Publications-and-media/Blogs-Landing-Page/NFPA-Today/Blog-Posts/2021/03/19/Introduction-to-Seismic-Protection-for-Sprinkler-Systems
A sprinkler system installed in a building that is subject to seismic activity may require seismic bracing by the local or state building code . If required, Chapter 18 of NFPA 13 outlines requirements for the seismic bracing, which includes bracing, flexible connections, pipe clearance to structural members, pipe restraint, and restrictions on the types of hangers and …
Seismic Compliance Frequently Asked Questions - HCAI
https://hcai.ca.gov/construction-finance/resources/seismic-faqs/
The Seismic Evaluation Procedures and Compliance Plan Regulations were developed by HCAI specifically for implementation by GAC licensed hospital buildings in furtherance of the Alfred E. Alquist of Hospital Facilities Seismic Safety Act of 1983. These regulations require GAC licensed hospitals to perform seismic evaluations on their respective facilities and for mitigation of …
Seismic Building Code Provisions for New Buildings …
https://www.fema.gov/sites/default/files/2020-10/fema_seismic-building-code-provisions-new-buildings-create-safer-communities_fact-sheet.pdf
Development of Seismic Regulations for New Buildings, as developed by the Building Seismic Safety Council of the National Institute of Building Sciences, based on ATC 3-06. 1989 ..... Loma Prieta Earthquake, M6.9, 63 Deaths, $12.1B Losses* 1992 All three model codes required seismic designs consistent with the NEHRP Provisions. 1994 .....
INSTALLING SEISMIC RESTRAINTS FOR DUCT AND …
https://mitigation.eeri.org/files/installing_seismic_restraints_ducts_pipes.pdf
Duct and Pipe Bracing Layout Step 1: Lay out supports or refer to drawings A run is a single straight section of duct or piping. Any change in direction is considered a new or different run. Offsets within a run may be allowed if the offset is less than the recommended spacing divided by 16 or as allowed by approved construction documents.