NFPA 13 Seismic Bracing Requirements: Cable Sway …
https://blog.qrfs.com/320-nfpa-13-seismic-bracing-requirements/
Fire sprinkler pipe also needs to handle the strain. Fire sprinkler pipe must also meet certain maximum allowable loads when it is braced against earthquakes. The resistance to lateral sway provided by lateral braces is applied in a gradient to the pipe. Thus, the pipe can move very little where the brace attaches to it.
Fire Sprinkler Hanging & Bracing Products - ERICO
https://www.nvent.com/sites/default/files/acquiadam/assets/B1230B-USEN.pdf
seismic sway bracing for non-structural components, such as fire sprinkler, mechanical, electrical and plumbing systems. The innovative line of nVent CADDY Bracing Systems was developed to help keep fire sprinkler systems intact after a seismic event and to minimize water damage resulting from leaks or ruptures.
Seismic Bracing and Calculations
https://www.kamal-mech-engr.com/seismic-bracing-calculations
This technique is known as seismic bracing, or sway bracing. NFPA 13 requires seismic bracing for fire sprinkler risers, main lines, and branch lines 2.5 inches or larger. Pipe smaller than these areas is generally more flexible and requires only vertical restraint rather than bracing.
Sway Bracing | UpCodes
https://up.codes/s/sway-bracing
If a shared support structure is used to support sprinkler pipe and other distribution systems per 9.1.1.3.1 and that structure does not provide seismic resistance as required in 9.3.5.1.4, the following shall be met: The sprinkler pipe shall be braced using the method in 9.3.5.6 with the zone of influence including the water-filled sprinkler pipe and all other distribution systems …
Seismic Design For Fire Sprinkler Systems – Part 2c: …
https://www.scandaliato.com/seismic-design-for-fire-sprinkler-systems-part-2c-clearance-and-sway-bracing/
Sway Bracing The fourth and most commonly referenced seismic restraint design feature is sway bracing. Unlike in other plumbing systems, the water and pipe that comprise fire protection systems are lifesaving features. …
TOLCO seismic bracing - Eaton
https://www.eaton.com/content/dam/eaton/products/support-systems/tolco-seismic-bracing/seismic-bracing-ul-fm-approved-fire-sprinkler-systems-flyer-sa309005en.pdf
“Lateral sway bracing shall be provided on all feed and cross mains regardless of size and all branch lines and other piping with a diameter of 21/2 inches (65mm) or larger.”* • Fig. 1001 sway brace attachment •. 980 universal swivel sway braceFig attachment • 1" (or up to 2") schedule 40 brace pipe • wn in image on the right attached Sho