Interested in racing? We have collected a lot of interesting things about Steam Tracing Caustic Lines. Follow the links and you will find all the information you need about Steam Tracing Caustic Lines.


Steam Tracing - an overview | ScienceDirect Topics

    https://www.sciencedirect.com/topics/engineering/steam-tracing
    none

Caustic Lines - Chemical plant design & operations - Eng …

    https://www.eng-tips.com/viewthread.cfm?qid=151233
    To follow up on the excellent comments by sshep, steam tracing of caustic-carrying lines (carbon steel lines, in particular) can be quite dangerous if the tracing lines touch the caustic lines. Hot caustic causes embrittlement of any weld joints in the caustic lines. Hot caustic can actually cause carbon steel piping to literally "fall apart".

What’s the Caustic Cracking in the steam pipeline?

    https://www.wldsteel.com/whats-the-caustic-cracking-in-the-steam-pipeline/
    The sensitive potential of caustic cracking of low carbon steam pipeline steel in boiling 35%~40% NaOH solution is -1150~800mV (SCE), and the potential of caustic cracking occurs in the range of -700mV (SCE) at boiling …

Heat Tracing of Piping Systems - Effective Steam Tracing

    https://wermac.org/documents/steam_tracing.html
    The most common diameters of steam tracing are 3/8 in. (9.52 mm) and 1/2 in. (12.7 mm) OD copper or stainless steel tubing. Diameters of 5/8 in. (15.88 mm) and 3/4 in. (19.05 mm) OD tubing have been used; however, this entails greater expense. Tubing that is 3/8 in. is more easily plugged by sediment and/or debris, so it is less frequently used.

A Case Study on Caustic Corrosion in Refinery Piping

    http://ijeit.misuratau.edu.ly/wp-content/uploads/2016/11/2-8.pdf
    Pipe skin temperature is measured at some locations and found approx. = 55 °C on 2" caustic pipe and 87°C on 1/2" steam tracing piping. Steam tracing was found online even without caustic transfer (intermittent). Figure 2a. Caustic Gouging Figure 2b. Caustic Embrittlement (CSCC) III. …

STEAM TRACER LINE APPLICATIONS - Armstrong International

    https://www.armstronginternational.com/sites/default/files/resources/documents/steamtraplineapp.pdf
    On horizontal fluid lines, tracing steam generally flows in the opposite direction of the fluid in the pipe, but it must be installed to allow the condensate to drain by gravity.Low points which can cause stagnation and the resulting cold spots should be avoided. Generally when a single tracer line is used, the line is placed under the fluid pipe.

DESIGN GUIDE - Thermon

    https://content.thermon.com/pdf/ca_pdf_files/TSP0013-Steam-Tracing-Design.pdf
    Step 2: Select the Proper Thermon Steam Tracing Method For a steam tracing system to perform at optimal levels, choose the type of tracer that most closely meets the process design requirements using Table 2.1 below. Table 2.1 Process Temperature vs. Tracer Type Pipe Size in (mm)50°-100°F (10°-38°C)(39°-66°C) 151°-200°F (67°-93°C)

Technical Specification Guide for Steam Tracing and …

    https://www.armstronginternational.com/sites/default/files/resources/files/Guide%20to%20Steam%20Tracing%20and%20Condensate%20Collection.doc
    tracer piping on mea, acid, caustic, phenol, and liquid benzene lines, and on instrument leads handling volatile stocks, shall be separated from these lines by a one inch (1") wide non-asbestos tape, suitable for a temperature of 400°f, wrapped around the steam line to a thickness of about ½”, spaced at a maximum of 18" o.c. separation may also …

Water treatment: Temperature maintenance & caustic lines

    https://www.thermon.co.za/case-study/the-critical-role-of-temperature-maintenance-in-caustic-lines
    With the introduction of a simple heating design on the tanks and trace heating on the pipelines, it is easily possible to store, deliver and process with high caustic concentrations resulting in more efficient systems. Thermon is a specialist in applying …

50% Caustic Piping in Cold Climate - CR4 Discussion Thread

    https://cr4.globalspec.com/thread/23272/50-Caustic-Piping-in-Cold-Climate
    Quite. Self-regulating electric trace heating tape, covered with a substantial quantity of pipe heat insulation and protected from water ingress, will do the job. Steam has also been used to trace-heat caustic lines in heritage installations, 1/4" copper pipework for the steam being secured to the process pipe before the insulation goes on.

Got enough information about Steam Tracing Caustic Lines?

We hope that the information collected by our experts has provided answers to all your questions. Now let's race!