Interested in racing? We have collected a lot of interesting things about Usg Seismic Bracing. Follow the links and you will find all the information you need about Usg Seismic Bracing.
Seismic | USG
https://www.usg.com/content/usgcom/en/performance-applications/performance/seismic.html
Building usage. Seismic Use Group III: essential facilities such as hospitals, fire departments and police departments that must function both during and after an earthquake. Seismic Use Group II: buildings that constitute a substantial public hazard, such as power plants and those that house over 300 people. Seismic Use Group I: everything else.
Seismic Technical Guide - USG
https://www.usg.com/content/dam/USG_Marketing_Communications/united_states/product_promotional_materials/finished_assets/seismic-technical-guide-suspended-ceiling-seismic-assemblies-en-SC2233.pdf
Splay bracing connection strength Not required Required Required 200 lbs or the design load, whichever is greater Partition attachment Allowed only if ceiling is able Bracing independent of ceiling Allowed with bracing to move laterally splay bracing Seismic separation joint Not required Required for areas > 2,500 sq. ft. Not required
Standard Seismic Applications Guide - IBC Category C | USG
https://www.usg.com/content/usgcom/en/performance-applications/performance/seismic/ibc-category-c.html
The following are all the IBC Category C 2 Code Requirements for lay-in acoustical panels and direct-hung acoustical tiles. The specifications below are for standard applications. View an alternate solution that delivers additional options. Basic Connections, Perimeter, and Lateral Splay Bracing. Requirements.
Technical Document Seismic Technical Guide - USG
https://www.usg.com/content/dam/USG_Marketing_Communications/united_states/product_promotional_materials/finished_assets/seismic-technical-guide-partition-attachment-en-SC2505.pdf
Technical Seismic Technical Guide Document Partition Attachment Code Requirements1 The International Building Code (IBC) definesthe requirement for the lateral bracing of non-structural partitions also known as partition attachment. Generally, partition attachment and their supports and attachments must be definedin the project drawings.
Technical Document Seismic Technical Guide - USG
https://www.usg.com/content/dam/USG_Marketing_Communications/united_states/product_promotional_materials/finished_assets/seismic-technical-guide-suspended-drywall-ceiling-construction-en-SC2495.pdf
splay bracing. This is due to the diaphragm strength achieved by screw-attached gypsum board. In addition, there are no lay-in ceiling panels that can become dislodged. For these suspended drywall ceiling applications in seismic design categories A-F, we offer the USG® drywall
Technical Document Seismic Technical Guide - USG
https://www.usg.com/content/dam/USG_Marketing_Communications/united_states/product_promotional_materials/finished_assets/seismic-technical-guide-hanger-wire-attachment-en-SC2522.pdf
USG Donn® main tees are produced with round hanger wire holes in the tee web at regular intervals. There are also rectangular (convenience) holes located in the tee bulb at regular intervals. The typical location for the hanger and bracing (splay) wires is in the round holes, but the rectangular (convenience) holes may also be used when needed.
Technical Document Seismic Technical Guide - USG
https://www.usg.com/content/dam/USG_Marketing_Communications/united_states/product_promotional_materials/finished_assets/seismic-technical-guide-specialty-decorative-ceilings-en-SC2494.pdf
USG has a long history of product development and innovation for suspended ceiling systems in seismic applications and continues to commit significant resources to this endeavor. We have thoroughly examined our specialty ceiling offerings for seismic design categories C-F. The findings of this study and our recommendations
Seismic Hazard Maps and Site-Specific Data - USGS
https://www.usgs.gov/programs/earthquake-hazards/seismic-hazard-maps-and-site-specific-data
Vs30 Data. Global data and U.S. data compilations. Urban Seismic Hazards. Includes California, Central and Eastern U.S., Pacific Northwest hazard maps and data. Foreign Hazard Maps. Includes Afghanistan, Sumatra, State of Gujarat,India. See also Global Earthquake Model (GEM).
Seismic Solutions
https://www.usgme.com/solutions/details/index/id/6
Horizontal restraint (splay wires or rigid bracing) within 2" of intersection and splayed 90° apart at 45° angles. Required. Compression posts (struts) 12' o.c. in both directions, starting 6' from walls. Required. Splay bracing connection strength 200 lbs or …
damage and maintain ceiling integrity Standard DX system
http://usg.de/fileadmin/media/DONN_DX_Downloads/SCAND/8.DONNDXSeismic_ENG_0604e_01-395kB.pdf
special bracing •P atented QUICK-RELEASE ™ Clip provides superior pull out strength of 180kg • Unique capability to resist seismic •T ested to meet ASTM seismic resistance standards •C omprehensive design and installation recommendations are available from USG Technical Services Main tee and cross tee connection. Wa ll bracing
Got enough information about Usg Seismic Bracing?
We hope that the information collected by our experts has provided answers to all your questions. Now let's race!